ATTOM UPS Dubai. When the Grid Cuts at 2PM in August, Your UPS Has One Job.
The ATTOM AgilePower is a true online double-conversion UPS designed for IT environments that cannot afford a second failure. Wide input voltage for UAE grid conditions. 150% overload capacity for motor startup current. Hot-swap modular expansion without a maintenance window. 1kVA to 600kVA in Dubai stock.
Three Lines. One Decision.
Which ATTOM Online UPS Is Right for Your Installation
The ATTOM AgilePower range covers single-phase server rooms, three-phase commercial installations, and data centres requiring modular scalability. The three lines are architecturally different — the right starting point depends on your load and what happens to it over the next three years.
1kVA to 60kVA
The core commercial online UPS for server rooms, network rooms, and IT racks. Standard 19-inch design, fits into any rack cabinet. Single phase models from 1kVA to 10kVA. Three phase from 10kVA to 60kVA. UAE supply voltage 230V and 400V. Wide input tolerance handles generator supply and fluctuating grid voltage without unnecessary battery transfers.
Best for server rooms, IT racks, network rooms, edge deployments, clinic and clinic IT rooms, small data rooms.
3kVA to 5kVA Lithium
The dedicated 48V lithium battery online UPS. Same rack form factor as the standard range — 3U, 19-inch — but built specifically for 48V LiFePO4 battery packs. Output PF=1. 50A maximum charging current for fast lithium charge. The parallel capability — up to 9 units in one group — makes this the correct choice for server rooms requiring N+1 or 2N redundancy without large single units.
Best for server rooms upgrading from lead-acid to lithium, N+1 redundancy designs, edge data rooms where long battery life matters.
45kVA to 600kVA
The enterprise and data centre UPS. IGBT three-level topology, dual DSP control, hot-swappable 20/25/30kVA power modules. PF=1 output. ECO mode, EPO, 4.3-inch touch colour LCD. The architecture that lets you start at 40kVA and expand to 600kVA without taking the server room offline. Designed for IT environments where the load grows incrementally and a maintenance window for UPS upgrade does not exist.
Best for data centres, virtualised IT environments, hospitality, commercial buildings, telecom, and any installation requiring expansion without downtime.
Not sure which line? WhatsApp us your load in kW, the phase supply (single or three phase), and whether you need runtime beyond 10 minutes. We specify the correct model, confirm Dubai stock, and return AED pricing the same day.
What the Brochure Doesn't Say
Eight Decisions Built Into the AgilePower That Matter in UAE Conditions
These are engineering choices that determine how a double-conversion online UPS actually performs over five years in Dubai — not in a European test environment on day one.
When grid power fails in a Dubai commercial building, everything on the UPS demand curve spikes simultaneously. Servers stay at their normal load. HVAC compressors restart and draw 3 to 5 times their running current during startup. Lift motors do the same. A standard online UPS system handles 125% of rated load for a short period before tripping to bypass.
The ATTOM AgilePower modular UPS handles 110% for 60 minutes, 125% for 10 minutes, and 150% for 1 minute. That first minute — while motors are starting and load is unsteady — the UPS absorbs the surge and holds. A 45kVA unit supplies 67.5kVA in that window. Protected equipment continues without interruption.
This is not a theoretical specification. It is the engineering answer to a real failure mode: the UPS that trips at the worst possible moment because the startup load exceeded a narrow tolerance window.
The AgilePower modular UPS uses IGBT three-level NPC topology with dual DSP control. Three-level topology switches at half the DC bus voltage on each cycle — compared with the full bus voltage in two-level designs. Lower switching voltage means less heat per switching event, less electromagnetic stress on the semiconductors, and significantly lower output voltage distortion.
The practical result: output THDv below 1% on three-phase models at linear load. Your servers, switches, and storage equipment receive power from the UPS that is cleaner than typical UAE grid supply. Clean power means lower failure rates in sensitive electronics over time. Lower failure rates mean fewer replacement cycles.
The dual DSP control architecture provides a redundant control path — if one DSP encounters a fault condition, the second continues managing the conversion without interrupting output. For an online double-conversion UPS in a UAE data centre that cannot afford a control-plane failure: this is the design that prevents it.
The AgilePower rack mount UPS accepts single-phase input voltage from 160V to 300Vac without transferring to battery. Three-phase models accept 208V to 478Vac.
This matters in Dubai for two reasons. First: older commercial buildings, industrial zones and free-zone properties sometimes experience voltage that sags during peak summer HVAC load. A narrow-tolerance online UPS transfers to battery on every sag event — running down the battery on non-outage events. When the real outage comes, battery reserve is already degraded. The 160–300V window means the AgilePower stays on mains through voltage fluctuation and uses battery only for actual power failures.
Second: generator supply. Generator output voltage and frequency are rarely as stable as grid supply, particularly during the first 30 to 60 seconds after startup. The wide input range and 40–70Hz frequency acceptance means the UPS accepts generator supply without requiring an additional automatic voltage regulator between generator and UPS.
The conversation every growing IT team has eventually: the server room load has exceeded the UPS capacity. The next tier up requires a maintenance window. The business cannot afford a maintenance window. The UPS stays undersized. The risk accumulates.
The AgilePower modular UPS is designed to eliminate this conversation permanently. Each power module — 20kVA, 25kVA, or 30kVA, in a 2U or 3U form factor — is inserted from the front of the cabinet during live operation. The cabinet controller detects the new module, validates it, and begins distributing load across the expanded module count automatically. Protected equipment runs throughout. There is no switchover event.
One cabinet scales from 45kVA to 200kVA. Parallel cabinets extend to 600kVA. For a Dubai data centre, colocation facility, or enterprise IT room that knows the load will grow but cannot predict by how much or when — pay for the capacity you need now and expand when the load demands it, on your timeline, not the UPS's.
A UPS running at 20% load is less efficient than the same UPS running at 60% load. Most online UPS systems accept this inefficiency silently. The AgilePower modular UPS does not.
The system's intelligent load management monitors total load percentage continuously. When the load falls below the efficient operating range for the number of active modules, the system automatically places surplus modules into standby mode — concentrating the load across fewer modules, raising each module's utilisation ratio, and improving overall system efficiency. Modules in standby remain ready to activate instantly if load increases.
The ECO mode function provides a second efficiency layer — at stable grid conditions, the load passes through with the inverter in warm standby, ready to take over within milliseconds if supply quality degrades. For a Dubai server room running 24 hours a day, 365 days a year, the cumulative DEWA bill difference between an efficient UPS and an inefficient one is measurable over a three-year period.
Most lithium batteries designed for energy storage use CAN bus protocol — Pylontech, Dyness, and most solar storage brands included. CAN bus requires the UPS or inverter to support the battery's specific message format. DIP switch setting on the battery, correct firmware version on the UPS, correct CAN cable. If one element is wrong the systems cannot communicate. The UPS falls back to voltage-based charging. Lithium batteries charged on voltage-based control without BMS communication age faster.
The ATTOM AgileLi communicates via RS485 serial and digital output (DO). RS485 is a standard serial interface supported by virtually every enterprise UPS. The digital output provides dry contact alarm signals independently. No pairing. No DIP switch. No protocol version matching.
The AgileLi's intelligent BMS handles all cell-level protection independently — over-current, over-charge, over-discharge, short-circuit, and intra-module cell balancing. Cycle life: 4,000 cycles. Parallel up to 16 sets. Rack mount, rear wiring, 4U form factor on the smallest models. For a Dubai server room upgrading from dead VRLA to lithium without a system redesign — this is the path.
The AgilePower rack modular UPS carries a 4.3-inch colour touch LCD on the front panel. Load percentage, battery state of charge, input and output voltage, frequency, alarm history — visible and configurable from the panel without a laptop or a network connection. For a facilities manager doing a walk-through: the UPS tells you its status the moment you stand in front of it.
For the network team who monitors everything remotely: the optional SNMP card integrates the UPS into any network management system or DCIM platform. The rack mount range includes RS232 as standard with SNMP available as an option. Alarm notifications, battery health reports, and load trending data are available through the same management interface used for the rest of the infrastructure.
The Modbus protocol option on the lithium variant additionally supports integration into industrial building management systems — relevant for UAE commercial buildings where the BMS and IT infrastructure share a monitoring layer.
Output power factor tells you how much of the UPS's rated kVA actually delivers working kilowatts to connected equipment. A UPS with PF=0.8 rated at 10kVA delivers 8kW of real power. A UPS with PF=1 rated at 10kVA delivers the full 10kW.
The ATTOM AgilePower rack mount single-phase models at 1kVA to 3kVA carry PF=0.8 — this is standard for small single-phase UPS at this capacity range. From 6kVA upward, all models carry PF=1 — including the three-phase rack mount range and the modular UPS. The lithium variant (3kVA and 5kVA) also carries PF=1.
For Dubai server rooms and commercial IT installations: specify the load in kW, not in kVA, and match the UPS to the kW figure on PF=1 models. The same load that requires a 12.5kVA unit on a PF=0.8 UPS requires only a 10kVA unit on a PF=1 model. One tier difference. Measurable cost saving at every procurement cycle.
Dubai Stock
ATTOM AgilePower UPS — Full Specification Table
All models are true online double-conversion. All support UAE 230V single phase and 400V three phase at 50Hz. Prices in AED — WhatsApp for same-day quote on any model.
| Model | Phase | Capacity | Output PF | Efficiency | Key Spec |
|---|---|---|---|---|---|
| Rack Mount — Standard (VRLA Battery) | |||||
| U-001R11H / U-002R11H | Single | 1–2kVA | 0.8 | 89–90% | 24/36Vdc battery · input 160–300Vac |
| U-003R11H | Single | 3kVA | 0.8 | 90% | 48/72Vdc battery · input 160–300Vac |
| U-006R11H PF=1 Start | Single | 6kVA | 1.0 | 94% | 240Vdc battery · parallel ×3 · SNMP opt. |
| U-010R11H | Single | 10kVA | 1.0 | 94% | 240Vdc battery · parallel ×3 · SNMP opt. |
| U-010R33H to U-060R33H | Three 400V | 10–60kVA | 1.0 | 95.5% | 384–480Vdc battery · THDv ≤1% · parallel ×3 |
| Rack Mount — Lithium Battery Variant | |||||
| U-003R11E Lithium | Single | 3kVA | 1.0 | 93.5% | 48Vdc LiFePO4 · parallel ×9 · SNMP + Modbus |
| U-005R11E Lithium | Single | 5kVA | 1.0 | 94% | 48Vdc LiFePO4 · 50A charge · parallel ×9 |
| Rack Mount Modular — Hot-Swap Expansion | |||||
| U-045M33H | Three 400V | 45kVA | 1.0 | High | IGBT 3-level · hot-swap modules · 150% overload · 4.3" LCD |
| U-060M33H to U-090M33H | Three 400V | 60–90kVA | 1.0 | High | ECO mode · EPO · 20/25/30kVA modules · dual DSP |
| U-150M33H to U-200M33H Data Centre | Three 400V | 150–200kVA | 1.0 | High | Parallel cabinets to 600kVA · intelligent module standby |
Three-phase rack mount (U-010R33H to U-060R33H): Input 208–478Vac, battery 384–480Vdc, output THDv ≤1% on linear load — the cleanest output in the standard rack range. If your server room is on three-phase 400V supply and you need under 60kVA, this is the correct specification.
UAE Installation
Three Things That Are Different About UPS in Dubai
European UPS specifications are written for stable 230V supply, 25°C ambient, and VRLA batteries that achieve their rated lifespan. Dubai is different on all three. Here is how the AgilePower addresses each.
Grid Voltage and Generator Compatibility
UAE grid voltage is 230V single phase, 400V three phase at 50Hz. The AgilePower accepts 160–300V single phase and 208–478V three phase — a wider tolerance than most online UPS systems. This matters for buildings that also run on generator supply where output voltage varies during startup and stabilisation.
The 40–70Hz frequency acceptance handles generator output frequency variation without battery transfer. The UPS does not deplete battery reserve on every generator startup event. Battery remains reserved for actual power failure.
Heat and Battery Life
VRLA battery capacity degrades faster at elevated temperatures. In a Dubai plant room running at 35°C, a battery rated for five years at 25°C may fail within three years. The AgilePower's intelligent battery management monitors actual health continuously — not estimated remaining life from a calendar date.
The lithium variant (U-003R11E / U-005R11E) uses 48V LiFePO4 which is less sensitive to temperature than VRLA and delivers far more discharge cycles before degradation becomes significant. For UAE server rooms where ambient temperature is a known accelerant of lead-acid failure — the lithium variant addresses the root cause.
Simultaneous Load Spikes at Power Failure
In a Dubai commercial building, power failure on a summer afternoon means HVAC compressors, server room cooling, lifts, and IT equipment all attempt to restart or continue simultaneously. The first minute after grid failure is the highest-demand moment.
The AgilePower modular UPS handles 150% of rated capacity for 1 minute — the motor startup window. A 45kVA unit supplies 67.5kVA during that first minute. Standard online UPS systems typically trip at 125% brief overload. The extra 25% headroom is the difference between the UPS holding the load and the UPS creating a second problem during the outage.
Battery Option
AgileLi — The Lithium UPS Battery That Communicates via RS485. No CAN. No DIP Switch.
Most lithium batteries designed for energy storage use CAN bus protocol — and that protocol requires pairing. DIP switch configuration on the battery, a specific CAN cable, and an inverter that supports the exact protocol version. If one element is wrong the systems cannot communicate. The AgileLi takes a different approach.
Simple Serial. Not a Custom Protocol. Any UPS With an RS485 Port Accepts It.
Solar storage batteries — Pylontech, Dyness and similar — use CAN bus protocol. CAN bus requires the inverter to support the specific battery brand's message format. Wrong DIP switch setting, wrong firmware version, or wrong cable type and the battery and inverter cannot talk. The UPS falls back to voltage-based charging, which accelerates lithium aging.
The ATTOM AgileLi communicates via RS485 and digital output (DO). RS485 is a simple industry-standard serial interface supported by virtually every enterprise UPS — APC, Eaton, Vertiv, and the ATTOM AgilePower. The digital output provides dry contact alarm signals independently of the serial link. No pairing handshake. No protocol version matching. No DIP switch.
The AgileLi's own intelligent BMS handles all cell-level protection independently — over-current, over-charge, over-discharge, short-circuit, intra-module cell balancing. The BMS also handles state-of-charge monitoring with SOC minimum ≤5% before low-battery alarm. The UPS manages charge voltage; the BMS manages cell safety. Both do their job without needing to negotiate a protocol.
Cycle life: 4,000 cycles. Parallel expansion: up to 16 sets. Self-discharge: less than 3% per month. Operating temperature: 0–40°C — correct for UAE server room ambient conditions.
The Models That Fit in a Standard Server Room Rack
The AgileLi UPS battery range starts at 4U rack height — the practical size for server room and data room deployment. All models are 440mm wide (standard rack width), rear wiring, in-rack mount. LiFePO4 chemistry — the safest lithium for enclosed spaces, thermally stable, no thermal runaway risk under overcharge or mechanical stress.
The models below are the rack-deployable range. Voltage architecture spans from 102.4V to 409.6V, matching external battery bus voltages used by 10kVA and above enterprise UPS systems. WhatsApp your UPS model and battery bus voltage to confirm the correct AgileLi model before ordering.
| Model | Ah | Voltage | kWh | Max Discharge | Form Factor | Weight |
|---|---|---|---|---|---|---|
| B-025E096RL | 25Ah | 102.4Vdc | 2.56kWh | 100A (4C) | 4U rack | 40kg |
| B-025E192RL | 25Ah | 204.8Vdc | 5.12kWh | 100A (4C) | 4U rack | 60kg |
| B-025U192RL | 25Ah | ±102.4Vdc | 5.12kWh | 100A (4C) | 4U rack | 60kg |
| B-025E384RL | 25Ah | 409.6Vdc | 10.24kWh | 100A (4C) | 8U rack | 120kg |
| B-025U384RL | 25Ah | ±204.8Vdc | 10.24kWh | 100A (4C) | 8U rack | 120kg |
All models: LiFePO4 · RS485/DO communication · 4,000 cycle life · 0–40°C · <3%/month self-discharge · parallel up to 16 sets · optional LCD for BMS status display. WhatsApp your UPS model and battery bus voltage — we confirm the correct model and AED pricing same day.
MEA Supply
ATTOM AgilePower UPS Supply Across MEA — From Dubai Stock
The AgilePower range supports multiple voltage specifications — 208V, 220V, 230V, 240V, 380V, 400V, 415V — making it suitable for procurement teams in MEA markets with varying grid standards. Stock confirmed before payment. AED and USD pricing available. WhatsApp for availability and bulk order terms.
Saudi Arabia · Qatar · Kuwait · Bahrain · Oman · Jordan · Iraq · Lebanon · Egypt
Nigeria · Ghana · Kenya · Tanzania · Uganda · Rwanda · Ethiopia · South Africa · Zambia · Zimbabwe · Mozambique · Ivory Coast · Senegal · Cameroon · Angola · DR Congo · Gabon · Botswana · Namibia · Malawi
Kazakhstan · Uzbekistan · Kyrgyzstan · Tajikistan · Turkmenistan · Azerbaijan · Armenia · Georgia
Common Questions
Frequently Asked Questions — ATTOM UPS Dubai
Related Pages
Other UPS and Power Solutions From Vector Dubai
Power protection and infrastructure from Dubai since 2010.
Same Day Response
Tell Us the Load in kW. We Tell You the Model and the AED Price.
WhatsApp us the load in kW and the phase supply. We specify the correct ATTOM AgilePower model, confirm Dubai stock, and return AED pricing the same day. No forms. No waiting.
Vector Dubai · International City, Dubai · sales@vdsae.com · Mon–Sat 8AM–6PM
About ATTOM AgilePower UPS · Vector Dubai
Vector Dubai (vdsae.com) supplies ATTOM AgilePower online UPS systems in Dubai and across the UAE. ATTOM (Attom Technology) is a data centre infrastructure company manufacturing online UPS systems, precision cooling, modular data centres, racks and DCIM solutions. AgilePower UPS models available: rack mount single phase 1kVA to 10kVA, rack mount three phase 10kVA to 60kVA, rack mount lithium variant 3kVA to 5kVA with 48Vdc LiFePO4 battery, rack mount modular 45kVA to 200kVA (parallel to 600kVA), and tower UPS 20kVA to 200kVA. All models are true online double-conversion UPS systems. Applications include online UPS for server rooms, server room UPS Dubai, three phase UPS for commercial buildings, modular UPS for data centres, rack UPS for IT infrastructure, double conversion UPS for critical loads, industrial UPS UAE, UPS battery replacement Dubai with AgileLi LiFePO4. PF=1 on 6kVA and above models. Input voltage tolerance 160–300Vac (single phase), 208–478Vac (three phase). Overload capacity 150% for 1 minute on modular range. SNMP monitoring standard on modular range, optional on rack mount. AgileLi lithium battery — no protocol coupling required, LiFePO4 chemistry, intelligent BMS, rear wiring rack installation. Supply across all seven UAE emirates and MEA. Contact WhatsApp +971 52 821 3639 or sales@vdsae.com. Monday to Saturday 8AM to 6PM.